Unterschiede

Hier werden die Unterschiede zwischen zwei Versionen gezeigt.

en:dsw-88-n [2018/04/19 03:50] (current)
Line 1: Line 1:
 +====== DSW-88-N ======
  
 +=== Data switch for the s88-feedback bus from the Digital-Professional-Series ! ===
 +
 +{{:de:foto:dsw-88-n_10_01.jpg}}
 +
 +==== The data switch DSW-88-N acts as a Y-cable which can divide the s88-bus. The below shown cable connects the module to the command station and the two above s88-cables are the two new s88-feedback lines, one to the right and one to the left side. ====
 +
 +Normally the s88-feedback bus expects all connected feedback modules behind each others in one line. The data switch **DSW-88-N** provides the possibility to split the s88-feedback output!
 +
 +The data switch **DSW-88-N** provides in addition **three 6-poles pin bars** for the **s88 standard connection** and as well three ***RJ-45 sockets** for a bus connection according to s88-N.
 +
 +{{  :de:cad:dsw-88-n_10.gif  }}
 +
 +==== For example: Your command station has been placed into the middle of the model railroad layout you do not need anymore to install a long feedback ring. You can now easily split the output after the data switch DSW-88-N for a separate left and right feedback line. ====
 +
 +{{  :de:cad:dsw-88-n_10_25.gif  }}
 +
 +==== Is the data switch DSW-88-N connected directly to the command station (here Intellibox) is it possible to build two feedback lines for left- and right-hand installation below the layout. If you require another splitting you can just insert one more data switch DSW-88-N into the line. ====
 +
 +====== Features of the DSW-88-N ======
 +
 +The **data switch DSW-88-N** can be used together with many **digital command stations** which dispose about the **s88-feedback bus**:
 +
 +^  __Digital command station / Interface __  __ \\  __  {{:de:images:blindgif.gif?230x1}}    ^  __DSW-88-N __  __ \\  __  {{:de:images:blindgif.gif?130x1}}  ^  __special features __  __ \\  __  {{:de:images:blindgif.gif?230x1}}  |
 +^**Control Unit + Interface 6051 **  |  yes  |  **-**  |
 +^**Control Unit + Memory**  |  yes  |  **-**  |
 +^**Central Station 1**  |  yes  |  **with ESU upgrade Reloadad**  |
 +^**Central Station 2**  |  restricted  |  **up to firmware 1.x**  |
 +^**Central Station 3**  |  no  |  **-**  |
 +^**S88 LINK L88 (60883)**  |  no  |  **-**  |
 +^**ECoS 1 (50000)**  |  yes  |  **-**  |
 +^**ECoS 2 (50200)**  |  yes  |  **-**  |
 +^**Intellibox 1**  |  yes  |  **-**  |
 +^**IB-COM**  |  yes  |  **-**  |
 +^**Intellibox 2**  |  yes  |  **-**  |
 +^**TWIN-CENTER**  |  yes  |  **-**  |
 +^**EasyControl**  |  yes  |  **-**  |
 +^**Viessmann Commander**  |  yes  |  **-**  |
 +^**HSI-88**  |  yes  |  **-**  |
 +^**HSI-88-USB**  |  yes  |  **-**  |
 +^**DiCoStation**  |  yes  |  **-**  |
 +
 +    * No additional power supply is required for the **data switch DSW-88-N**. It is suitable for 5 and 12V s88-bus voltage.
 +    * The feedback informations will be transfered through the data switch **without any delay**.
 +    * Each reading of feedback information started by the command station will report the information of all connected feedback modules to the central unit. First reading will be the information of the left line. Following the **data switch** will **change** to the right feedback line for transfer of those informations.
 +    *  The **data switch DSW-88-N** is compatible with all **s88-feedback modules available on the market**.
 +    * LDT-components from the **Digital-Professional-Series** can easily be used on any digital model railway layout.
 +    * The finished module in a case comes with **24 month warranty**.
 +    * Each **data switch DSW-88-N** will be supplied with a detailed **operating-/respectively assembly-instruction**. Those instructions can be found within the next section.
 +    * The data switch DSW-88-N is available as a **kit (-B)** or as checked **finished module in a case (-G)**.
 +
 +====== Downloads ======
 +
 +Instructions regarding this article can be found here: [[:en:dl_dsw_88_n|Downloads DSW-88-N]].\\
 +Instructions for all LDT-Components can be found here: [[:en:downloads|Overview Downloads]].
 +
 +====== Sample-Connections ======
 +
 +Sample-connections regarding this article can be found here: [[:en:ab_dsw_88-n|Sample-Connections DSW-88-N]].\\
 +Sample-connections for all LDT-Components can be found here: [[:en:anschlussbeispiele|Overview Sample-Connections]].\\
 +{{  :de:cad:page_1214.gif  }}
 +
 +====== Add to Wish List / Prices ======
 +
 +**Attention: Products can only be added to the Wish List, if you are registered as customer at the LDT WebShop or if you are initially registered by interest of our products.**
 +
 +^{{:de:images:noticelist_m.png}} |{{:de:images:blindgif.gif?550x1}}  \\ <html>Add to <b><u class="linkit" onclick="toNoticeList('040111');">Wish List</u></b></html>: **DSW-88-N-B** (Part-No.: 040111): **Data switch** for the s88-feedback bus as a **kit** (**32,50 €***).\\ <html>Add to <b><u class="linkit" onclick="toNoticeList('040113');">Wish List</u></b></html>: **DSW-88-N-G** (Part-No.: 040113): **Data switch** for the s88-feedback bus as a\\ **finished module in a case** (**49,90 €***).\\ {{:de:images:blindgif.gif?580x1}}\\  ** * All prices incl. VAT, plus Shipping.**  |
 +
 +----
 +
 +\\  
 +====== To assure a good connection: s88-Bus Cable! ======
 +
 +    * The **data switch DSW-88-N** will be **supplied without s88-bus cable**. **Please select** a **suitable bus cable** (length and style) at the following table. For the **s88-standard connection** we supply an **interference protected, twisted** s88-bus cable with **original s88-plugs** at **length of 0,5m, 1m and 2m**. **s88-standard connections** are always required for the **connection** of the **first feedback module** to the **command station** or **interface**.
 +
 +  * We offer for **s88-bus connections in accordance to {{:de:cad:s88n_250.gif?50x34}} a blue screened patch cable with RJ-45 plugs at four different length of 0,5 to 3m**.
 +
 +  * The feedback module **RM-88-N, RM-88-N-O and RM-GB-8-N** can be connected with the **data switch DSW-88-N** via **s88-standard connection "Kabel s88"** or via **"Kabel Patch"** according to**{{:de:cad:s88n_250.gif?50x34}}**.
 +
 +^**s88-standard connection with 2 original s88-plugs, gray cable, twisted, round. Plus pin bar for bus extension.**|
 +|[[:en:zubehoer#Extended_connection_cable_for_the_s88-feedback_bus|Kabel s88 0,5m]]  |
 +|[[:en:zubehoer#Extended_connection_cable_for_the_s88-feedback_bus|Kabel s88 1m]]  |
 +|[[:en:zubehoer#Extended_connection_cable_for_the_s88-feedback_bus|Kabel s88 2m]]  |
 +^**s88-connection according to {{:de:cad:s88n_250.gif?50x34}} with 2 RJ-45 plugs, 
 +blue cable, screened.**|
 +|[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 0,5m]]  |
 +|[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 1m]]  |
 +|[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 2m]]  |
 +|[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 3m]]  |
 +
 +Subject to technical changes and errors.\\
 +© 2018 by LDT\\  [[:en:dsw-88-n#dsw-88-n|{{  :de:images:zurueck_en_page.png?40x32}}]]
 
Recent changes RSS feed Creative Commons License Donate Powered by PHP Valid XHTML 1.0 Valid CSS Driven by DokuWiki Design by Chirripó