 +====== Light-DEC ======
  
 +== Universal Layout-Light-Control for analogue and digital model railway layouts which are operating self-sufficient with or without PC or digital command station. ==
 +
 +{{:de:foto:light-basis_light-dispaly_ic_640.jpg}} ==== The Layout-Light-Control Light-DEC consist of one Light-DEC-Basis-Module (at the picture right) and as minimum of one Light-Module (Light-Display – at the picture left – or Light-Power) which has to be plugged to the side of the Basic-Module. ====
 +\\  
 +
 +
 +====== Features of Light-DEC ======
 +
 +
 +With **Light-DEC** is a **universal solution** available for a free distribution of **up to 44 light-functions** onto **maximal 160 light-outputs**. Those functions can **be automatically switched specific on- or off during the running day-time**. If there are **more than 160 light-outputs required** can be **further Light-DEC Systems installed**.
 +
 +The **running day consist** of **four day phases: dawn, day, dusk, and night**. For **each day-phase** can be the **starting-time** and a **time factor individual defined**. Via the **time-factor** is it possible to **accelerate** the **time of the day-phases**.
 +
 +**The sense of the time factor** is to **reduce timely** a **model-railway day** as required.
 +**Model railway days** have mostly the **length of 15 to 60 Minutes**. On **Model railway exhibition layouts** is the **length** of a model-day mostly **15 Minutes long**: **10 Minutes day** and **5 Minutes dark**.
 +
 +The **model railway-night** is **optical impressive** but the various **interesting designed layout details** can only be clearly identified during a **longer light phases**.
 +With **Light-DEC** you can **reproduce this requirement optimal** on **your model railway layout**.
 +
 +The **Light-Control Light-DEC** can be **automatically started** as soon as **voltage will be supplied to the module**. But there is **a possibility** to start or stop **via an external push button or switch**. The **starting time** can be **free selected**.
 +
 +There are **8 clamps for push buttons or switches** available which are as well be **specific** via the **light function activated** or **deactivated**.
 +
 +**Light-DEC** is a product of our //**Digital-Professional Series**// and contains therefore a **digital input**:
 +
 +Therefore is it **possible** to **start or stop** the **Layout-Light-Control Light-DEC** as well via a DCC-Command. **Light-DEC** can be **activated** via this command e.g. from the **model railway control software**. Therefore will be the **model railway times** correspond to the **software** and is **synchronized** to the **layout-light-control**.
 +
 +Also the **light functions** can be **switched on or off** via **DCC commands**. On this way will be for example the **flash-light of a railway crossing activated or deactivated** from the **digital command station** or from the **model railway control software**.
 +
 +
 +====== Components of the Light-DEC ======
 +
 +The **Layout Light Control Light-DEC** is **modular** designed and can be therefore **optimal adapted** to **any layout size** and to **any individual requirement** at **very low cost**.
 +
 +{{:de:foto:light-basis_ic.jpg}} ==== Basic component of the Light-Control Light-DEC is the Light-DEC-Basis-Module. ====
 +\\  
 +
 +**It consist** of the **Light-DEC-Basis-Module** and min. one **Light-Module**, which has to be **plugged** onto the **side** of the **Basic-Module**.
 +
 +{{:de:cad:light-dec_01.gif}} ==== Basic unit of the Layout-Light-Control Light-DEC with the Light-DEC-Basis-Module (at the sample connection right) and the minimum of one Light-Module (Light-Display – at the sample connection left – or Light-Power), which has to be plugged to the side of the Basic-Module. ==== 
 +
 +**[[:en:light-display|Light-Display]]-Modules** have **40 outputs** which supply a current of up to **0.5 Ampere**. They are **optimal for** the application of **model incandescent lamps and LED**.  
 +
 +**[[:en:light-power|Light-Power]]-Module** with **24 outputs** supply a **maximum current** of **2.5 Ampere each output**. With reason to the **high output current** they are suitable to switch a **great number incandescent lamps** e.g. **light-poles for road illumination** at the **same time**.
 +
 +With one **Light-DEC Basis-Module** can be up to **160 light outputs** via **maximal 7 Light-Modules** controlled. In this process is it possible to **combine Light-Display-** and **Light-Power-Modules as required**. All **Light-Modules** can be **directly connected to each other**.
 +
 +If the **Light-Modules** shall be **installed at longer distances** for getting them **closer** to the **light sources** they shall be **connected to each other with screened interference protected Patch-Cable** (Computer Network cable).
 +
 +{{:de:cad:light-dec_07.gif}} 
 +
 +There are **44 Light functions** (e.g. **neon light, flash light, running light, traffic lights, rail crossing, television set, welding arc, car direction indicator, house illumination, fair places) for selection available**, which can be **individual assigned** to the **outputs** of the **Light-Modules**.
 +
 +The **Light-DEC Basis-Module** contains a **display** and **4 push buttons**, for adjusting **all settings at a clear motion**.
 +
 +**During operation** will be the **actual model time** indicated at the **display**. Additionally can be the **day phase** and the related **time factor** indicated. For the **voltage supply** of the **Layout-Light-Control Light-DEC** are **model railway transformers** and **DC-Current switched mode power supplies suitable**.
 +
 +====== Downloads ======
 +Instructions regarding this article can be found here: [[:en:dl_light_dec|Downloads Layout-Light-Control Light-DEC]] and [[:en:dl_light-module|Downloads Light-Module]].\\
 +Instructions for all LDT-Components can be found here: [[:en:downloads|Overview Downloads]].
 +
 +====== Sample-Connections ======
 +
 +Sample-connections regarding this article can be found here: [[:en:ab_light_dec|Sample-Connections Light-DEC]].\\
 +Sample-connections for all LDT-Components can be found here: [[:en:anschlussbeispiele|Overview Sample-Connections]].\\
 +{{  :de:cad:page_1601.gif  }}
 +
 +====== Add to Wish List / Prices ======
 +**Attention: Products can only be added to the Wish List, if you are registered as customer at the LDT WebShop or if you are initially registered by interest of our products.**
 +
 +^{{:de:images:noticelist_m.png}} |{{:de:images:blindgif.gif?500x1}}  \\ <html>Add to <b><u class="linkit" onclick="toNoticeList('810222');">Wish List</u></b></html>: **Light-DEC-Basis-F** (Part-No.: 810222): **Basic-Module** for the **Light-Control Light-DEC** as a **finished module** (**109,90 €***).\\  \\ <html>Add to <b><u class="linkit" onclick="toNoticeList('050031-l@n');">Wish List</u></b></html>: **Light-Display-B** (Part-No.: 050031): **Light-Display-Module** for the **Light-Interfaces\\ LI-LPT and LI-LAN** as a **kit** (**59,90 €***).\\ <html>Add to <b><u class="linkit" onclick="toNoticeList('050032-l@n');">Wish List</u></b></html>: **Light-Display-F** (Part-No.: 050032): **Light-Display-Module** for the **Light-Interfaces\\ LI-LPT and LI-LAN** as a **finished module** (**79,90 €***).\\  \\ <html>Add to <b><u class="linkit" onclick="toNoticeList('050062');">Wish List</u></b></html>: **Light-Power-F** (Part-No.: 050062): **Light-Power-Module** for the **Light-Interfaces\\ LI-LPT and LI-LAN** as a **finished module** (**84,90 €***).\\ {{:de:images:blindgif.gif?580x1}} \\  ** * All prices incl. VAT, plus Shipping.**  |
 +
 +
 +[[:en:light-dec#top|{{  :de:images:zurueck_en_page.png?40x32}}]] Subject to technical changes and errors.\\  © 2022 by LDT
 
Recent changes RSS feed Creative Commons License Donate Powered by PHP Valid XHTML 1.0 Valid CSS Driven by DokuWiki Design by Chirripó