+ | ====== RM-GB-8-N ====== | ||
+ | === 8-fold Feedback Module with integrated occupancy detector === | ||
+ | |||
+ | == for the s88-feedback bus for s88-standard connection and RJ-45 sockets in accordance to s88-N from the Digital-Professional-Series ! == | ||
+ | |||
+ | {{ :de:foto:rm-gb-8-n_11_01.jpg }} | ||
+ | |||
+ | ==== The feedback module RM-GB-8-N is equipped for s88-standard connections with 6-poles pin bars and for bus connections according to s88-N with screened RJ-45 sockets. ==== | ||
+ | |||
+ | ====== Features of the RM-GB-8-N ====== | ||
+ | |||
+ | * For the connection to **command stations** and **interfaces**, which supports the **s88-feedback bus**: e.g. | ||
+ | * **Märklin Interface** (up to 62 units), | ||
+ | * **Märklin Memory** (up to 6 units), | ||
+ | * **Central Station 1** and **2** (up to 62 units), | ||
+ | * **Central Station 3** and **3 plus** via L88 with 5V s88-bus voltage (up to 62 units per Bus 1 to 3), | ||
+ | * **Intellibox**/**TWIN-CENTER** (up to 62 units), | ||
+ | * **EasyControl** (up to 62 units), | ||
+ | * **ECoS** (up to 62 units), | ||
+ | * **Commander** (up to 62 units), | ||
+ | * **HSI-88(-USB)** (up to 62 units) und | ||
+ | * **DiCoStation** (up to 62 units). | ||
+ | |||
+ | * It is suitable for the **control of 8 track sections** with a **current load** up to **3 Ampere**. A **short peak current** up to **7 Ampere** will be **acceptable**. Isolated rails or track sections to be monitored have to be simply connected to the **output clamps** of the feedback module to get a **digital current supply**. The **track section** can be **isolated** on **one or on both sides**. | ||
+ | * The **8-fold feedback Module RM-GB-8-N** with **integrated track occupancy report** is separated into **two 4-fold occupancy devices**. Therefore is it possible to **monitor tracks of two different booster circuits**. The separation into two 4-fold track occupancy devices **simplifies** as well the **monitoring of reverse-loops**. More information about this issue can be found within the file [[:en:dl_rm_gb_8_n|Reversing loop monitoring]] at the download section. | ||
+ | * **Including an integrated voltage monitor**: If there is no voltage at the tracks (e.g. after short circuit) the occupied identification will be **"frozen"** during the interruption. | ||
+ | * For the feedback module is **no additional power supply** required. This **reduces** the **wiring effort**. | ||
+ | * The Feedback Module **RM-GB-8-N** is for **s88-standard connections** equipped with **6-poles pin bars** and for **bus connections according to s88-N** with **screened RJ-45 sockets**. | ||
+ | |||
+ | |**{{:de:cad:s88n_250.gif?101x68}}** ^ \\ Additional information about the **standard s88-N** which will be supported by other\\ manufacturers as well can be found here: [[http://www.s88-N.eu|http://www.s88-N.eu]].\\ {{:de:images:blindgif.gif?500x1}} | | ||
+ | |||
+ | * The **RM-GB-8-N shall be operated only** with a **s88-bus voltage of 5V**. If the **Digital-command station** or the **Interface** offers the possibility to use either **5V or 12V** for the **s88-buss voltage** the **5V has to be selected**. The operation at the **s88-connection** on the bottom of the **Märklin Central Station 3 (CS3) plus (60216)** with a **constant s88-bus voltage of 12 Volt** will **not be permitted** because this will **damage the feedback module**. Together with the CS3 (60116) and the CS3 plus (60216) is it possible to operate the **RM-GB-8-N** via the **Märklin Module L88 (60883)**. It is **absolutely required to set the L88 sliding switch** onto a **s88-bus voltage of 5Volt**. | ||
+ | * If the **screening** of the **bus connections in accordance to s88-N** requires a connection to the **layout ground** is it possible to **solder** a grounded cable to the **metal housing of a RJ-45 socket**. | ||
+ | |||
+ | {{ :de:cad:rm-gb-8-n_11_02.gif? }} | ||
+ | |||
+ | * The feedback module **RM-GB-8-N** can be **combined** as required with the feedback module **RM-88-N** / **RM-88-N-O** and **RM-DEC-88** / **RM-DEC-88-O** / **RM-GB-8** with the **s88-feedback module** from **Märklin** and other suppliers. | ||
+ | * The unit is available as ready to use **finished module**, as **finished module in a case** or as **kit** on a 110x96 mm printed circuit board with four fastening bores (an empty case LDT-02 and suitable assembly material can be found under [[:en:zubehoer#mon-set|Accessory]]). | ||
+ | * The feedback module **RM-GB-8-N** from the **Digital-Professional-Series** can be operated without any problem on your digital controlled layout because it is **100% compatible** to the s88-feedback bus. | ||
+ | * The finished module and the finished module in a case comes with **24 month warranty**. | ||
+ | * Each feedback module **RM-GB-8-N** will be supplied with a detailed **operating-/respectively assembly-instruction**. Those instructions can be found within the next section. | ||
+ | * You can purchase the feedback module as a **kit (-B)**, as tested **finished module (-F)** or as tested **finished module in a case (-G)**. | ||
+ | |||
+ | ====== Downloads ====== | ||
+ | |||
+ | Instructions regarding this article can be found here: [[:en:dl_rm_gb_8_n|Downloads RM-GB-8-N]].\\ | ||
+ | Instructions for all LDT-Components can be found here: [[:en:downloads|Overview Downloads]]. | ||
+ | |||
+ | ====== Sample-Connections ====== | ||
+ | |||
+ | Sample-connections regarding this article can be found here: [[:en:ab_rm_gb_8_n|Sample-Connections RM-GB-8-N]].\\ | ||
+ | Sample-connections for all LDT-Components can be found here: [[:en:anschlussbeispiele|Overview Sample-Connections]].\\ | ||
+ | {{ :de:cad:page_1078.gif }} | ||
+ | ====== Add to Wish List / Prices ====== | ||
+ | |||
+ | **Attention: Products can only be added to the Wish List, if you are registered as customer at the LDT WebShop or if you are initially registered by interest of our products.** | ||
+ | |||
+ | ^{{:de:images:noticelist_m.png}} |{{:de:images:blindgif.gif?500x1|}} \\ <html>Add to <b><u class="linkit" onclick="toNoticeList('320101');">Wish List</u></b></html>: **RM-GB-8-N-B** (Part-No.: 320101): **8-fold Feedback Module** with integrated\\ track occupancy report as a **kit** (**41,90 €***).\\ <html>Add to <b><u class="linkit" onclick="toNoticeList('320102');">Wish List</u></b></html>: **RM-GB-8-N-F** (Part-No.: 320102): **8-fold Feedback Module** with integrated\\ track occupancy report as a **finished module** (**54,90 €***).\\ <html>Add to <b><u class="linkit" onclick="toNoticeList('320103');">Wish List</u></b></html>: **RM-GB-8-N-G** (Part-No.: 320103): **8-fold Feedback Module** with integrated\\ track occupancy report as a **finished module in a case** (**59,50 €***).\\ {{:de:images:blindgif.gif?580x1}}\\ ** * All prices incl. VAT, plus Shipping.** | | ||
+ | |||
+ | ====== To assure a good connection: s88-Bus Cable! ====== | ||
+ | |||
+ | * The **feedback module RM-GB-8-N** will be **supplied without s88-bus cable**. **Please select** a **suitable bus cable** (length and style) at the following table. For the **s88-standard connection** we supply an **interference protected, twisted** s88-bus cable with **original s88-plugs** at **length of 0,5m, 1m and 2m**. **s88-standard connections** are always required for the **connection** of the **first feedback module** to the **command station** or **interface**. | ||
+ | |||
+ | * We offer for **s88-bus connections in accordance to {{:de:cad:s88n_250.gif?50x34}} a blue screened patch cable with RJ-45 plugs at four different length of 0,5 to 3m**. | ||
+ | |||
+ | * The feedback module **RM-88-N, RM-88-N-O and RM-GB-8-N** can be connected between each other either via **s88-standard connection "Kabel s88"** or via **"Kabel Patch"** according to**{{:de:cad:s88n_250.gif?50x34}}**. | ||
+ | |||
+ | ^**s88-standard connection with 2 original s88-plugs, gray cable, twisted, round. Plus pin bar for bus extension.**| | ||
+ | |[[:en:zubehoer#Extended_connection_cable_for_the_s88-feedback_bus|Kabel s88 0,5m]] | | ||
+ | |[[:en:zubehoer#Extended_connection_cable_for_the_s88-feedback_bus|Kabel s88 1m]] | | ||
+ | |[[:en:zubehoer#Extended_connection_cable_for_the_s88-feedback_bus|Kabel s88 2m]] | | ||
+ | ^**s88-connection according to {{:de:cad:s88n_250.gif?50x34}} with 2 RJ-45 plugs, blue cable, screened.**| | ||
+ | |[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 0,5m]] | | ||
+ | |[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 1m]] | | ||
+ | |[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 2m]] | | ||
+ | |[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 3m]] | | ||
+ | |||
+ | Subject to technical changes and errors.\\ | ||
+ | © 2016 by LDT\\ [[:en:rm-gb-8-n#rm-gb-8-n|{{ :de:images:zurueck_en_page.png?40x32}}]] |