Unterschiede
Hier werden die Unterschiede zwischen zwei Versionen gezeigt.
— |
en:twin-center_info [2019/10/08 11:19] (current) |
||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ====== LDT-Decoder using on TWIN-CENTER! ====== | ||
+ | {{:de:cad:twin-center_01_klein.gif?225x179 }} | ||
+ | |||
+ | {{ :de:images:blindgif.gif?344x103 }}The TWIN-CENTER transmits the Fleischmann owned FMZ-Format as well as the standardized **DCC-Format** to the Lok- or accessory-decoder. This enables the control unit to respond to the **LDT-Decoders** for the DCC-Format ([[:en:s-dec-4|S-DEC-4-DC]], [[:en:sa-dec-4|SA-DEC-4-DC]], [[:en:m-dec|M-DEC-DC]] and [[:en:ls-dec-db|LS-DEC]]). | ||
+ | |||
+ | {{ :de:cad:multi-digital.gif?200x142}} | ||
+ | |||
+ | The TWIN-CENTER provides the **s88-feedback bus** for the **feedback of events** from the tracks. The **LDT-Feedback Modules** [[:en:rm-88-n|RM-88-N]] and [[:en:rm-88-n-o|RM-88-N-O]] (both for quick action switches) and [[:en:rm-gb-8-n|RM-GB-8-N]] ((for track occupancy reports) as well as the Data-Switch [[:en:dsw-88-n|DSW-88-N]] can communicate with the TWIN-CENTER without any problems. | ||
+ | |||
+ | At the data file {{:en:anleitungen:twin-center_info_en.pdf|twin-center_info_en}} you will find recommandations and sample connections for the TWIN-Center in communication with **LDT-Components**. | ||
+ | |||
+ | ====== Recommandations for the installation of LDT-Decoder on TWIN-CENTER: ====== | ||
+ | |||
+ | ===== 1. Registration of DCC Decoder on TWIN-CENTER ===== | ||
+ | |||
+ | As per factory adjustment the TWIN-CENTER transmit FMZ-data to the decoder. To operate the **LDT**-Decoder the respective addresses have to be changed to **DCC**. | ||
+ | |||
+ | This operation is described within the TWIN-CENTER operating manual at paragraph **8.1 turnout/signals registered at the TWIN-CENTER** on page 39. | ||
+ | |||
+ | **Four statements have to be adjusted for each address:** | ||
+ | |||
+ | - The so-called **Virtual Address** (from 1 to 2048). This complies e.g. to the number of turnouts. | ||
+ | - The **Decoder Address** or the decoder number. There are values of 1 up to 512 adjustable. | ||
+ | - At the **decoder output** values between 1 to 4 can be adjusted (as all LDT-Decoder contain four outputs). | ||
+ | - The **Data Format**. It has to be set to **D** for DCC, if the **LDT**-Decoder shall take over the switch events. | ||
+ | |||
+ | As the required adjustments at the TWIN-CENTER will cause probably at first some problems, we have created a table for your assistance including all details for the first 512 virtual addresses. Please load the file {{:en:anleitungen:twin-center_address-table1.pdf|twin-center_address-table1}} to your PC. | ||
+ | |||
+ | ===== 2. Programming the decoder address ===== | ||
+ | |||
+ | During the operation at the **TWIN-CENTER** it can happen that after actuating the programming key the decoder will switch the turnout at output 1 immediately into a **fast sequence** such as it would confirm the programming of an address. In this case the **address repetition storage** of the **TWIN-CENTER** contains **by error data** on which the decoder is already reacting. | ||
+ | |||
+ | **Proceed now as follows:** | ||
+ | |||
+ | - **Programming** the decoder **immediately after switching-on** the command station, **before** any loc is travelling. | ||
+ | - Proceed with a **RESET** of the command station. All stored data will be preserved, only the **address repetition storage will be deleted**. On the **TWIN-CENTER** you have to activate at switched-on status the keys **GO** and **STOP** together until “reset” will be shown at the display. | ||
+ | |||
+ | ===== 3. Adjusting the switching times ===== | ||
+ | |||
+ | The TWIN-CENTER output is not a clear DCC-data format but a mixture of FMZ and DCC format. | ||
+ | |||
+ | **LDT-Decoder** are optimal tuned to this data format. But will the decoder not switch always reliable it is possible to adapt the TWIN-CENTER to the requirement.\\ \\ At the paragraph **8.5 Adjustment of switching time** (page 42 of the TWIN-CENTER Operating Manual) this procedure is explained in detail. The **factory adjustment** has been set for the minimal and maximal switching time of **50ms**. | ||
+ | |||
+ | Increase the minimum and maximum switching time in above case to **250ms**. | ||
+ | |||
+ | [[:en:twin-center_info#top|{{ :de:images:zurueck_en_page.png?40x32}}]] Subject to technical changes and errors.\\ | ||
+ | © 2019 by LDT |