> To overview: sample connections sorted by digital command stations
> To overview: sample connections sorted by digital components
> To product selection: Central Station 1 (60212) / Märklin-Motorola
> To product selection: Central Station 1 (60212) as well as with ESU Upgrade ''Reloaded'' / Märklin-Motorola
description | file | edition |
---|---|---|
Digital-current ring conductor with multiple supply connection | page_264 | 12/2005 |
External supply to the Decoder (AC voltage supply) | page_096 | 01/2020 |
Correct connection of the external AC supply voltage | page_510 | 01/2020 |
External supply to the Decoder (DC voltage supply) | page_1454 | 01/2020 |
Seperate digital-current conductor for the decoder | page_265 | 07/2020 |
Ring conductor to the decoder | page_266 | 07/2020 |
Suppression of interferences caused by end-off switched turnouts | page_238 | 01/2020 |
Reed contacts for feedback (standard) / s88 standard cable | page_695 | 07/2020 |
Reed contacts for feedback (opto) / s88 standard cable | page_716 | 07/2020 |
Track occupancy feedback via contact tracks (standard) / s88 standard cable | page_696 | 07/2020 |
Shuttle train line with contact tracks (standard) / s88 standard cable | page_766 | 07/2020 |
Track occupancy feedback via contact tracks (opto) / s88 standard cable | page_717 | 07/2020 |
Shuttle train line with contact tracks (opto) / s88 standard cable | page_767 | 07/2020 |
Shuttle train line with contact tracks (opto) and external supply voltage / s88 standard cable | page_946 | 07/2020 |
Track monitoring with isolated center conductor / s88 standard cable | page_634 | 04/2020 |
Track monitoring with total isolated track / s88 standard cable | page_635 | 04/2020 |
Track monitoring with two booster current circuits (with DB-2) / s88 standard cable | page_636 | 04/2020 |
Accelerated feedback via HSI-88 (with seperate transformer for HSI-88) / s88 standard cable | page_748 | 07/2020 |
Driving and switching with Central Station / feedback with HSI-88 | page_440 | 05/2020 |
Accelerated feedback via HSI-88-USB (with seperate transformer for HSI-88-USB) / s88 standard cable | page_753 | 07/2020 |
Driving and switching with Central Station / feedback with HSI-88-USB | page_466 | 05/2020 |
Numbering the feedback modules / s88 standard cable | page_783 | 07/2020 |
Numbering the feedback modules / s88 standard cable | page_777 | 07/2020 |
Data switch DSW-88-N on Central Station 1 (60212) (various feedback modules) | page_1207 | 05/2020 |
Data switch DSW-88-N on Central Station 1 (60212) (RM-88-N-O) | page_1208 | 05/2020 |
Connecting DigitalBooster DB-2 or DB-4 f via 5-poles booster bus | page_443 | 06/2013 |
Connecting the DigitalBooster DB-2 via 5-poles booster bus | page_444 | 06/2020 |
Connecting the DigitalBooster DB-2 via the 5-poles Märklin ribbon cable | page_445 | 06/2020 |
Connecting the DigitalBooster DB-4 via 5-poles booster bus | page_926 | 06/2020 |
Central Station 1 and DigitalBooster DB-4: Integrating Booster-Link (Fa. Tams) | page_1665 | 06/2020 |
Central Station 1 with two or more DB-4: Integrating Booster-Link (Fa. Tams) | page_1666 | 06/2020 |
Connecting the DigitalBooster DB-4 via CDE-booster bus | page_1166 | 06/2013 |
Connecting the DigitalBooster DB-4 via CDE-booster bus | page_1169 | 06/2020 |
WatchDog decoder WD-DEC with Central Station 1 and DigitalBooster DB-2 | page_498 | 03/2020 |
GBS-DEC-DC/MM: external switchboard panel PC-controlled and Central Station 1 (60212) | page_1519 | 03/2020 |
GBS-DEC-DC/MM: s88-feedback bus branching via Data switch DSW-88-N with Central Station 1 (60212) | page_1221 | 03/2020 |
GBS-DEC-s88: external switchboard panel PC-controlled with Central Station 1 (60212) and RM-88-N | page_1528 | 03/2020 |
GBS-DEC-s88: external switchboard panel PC-controlled with Central Station 1 (60212) and RM-GB-8-N | page_1514 | 03/2020 |
Subject to technical changes and errors.
© 2022 by LDT
Märklin and Motorola are registered trade marks.