for the s88-feedback bus for s88-standard connection and RJ-45 sockets in accordance to from the Digital-Professional-Series !
For the connection to command stations and interfaces, which supports the s88-feedback bus: e.g.
The feedback RM-88-N contains 16 inputs, which are switching against ground (as Märklin s88 / S88 AC).
Simple and safe connection of switch rails, contact rails, occupancy sensors and reed contacts etc. via screw clamps.
The feedback module RM-88-N is suitable for s88-standard connections with 6-poles pin bars and for bus connections according to s88-N equipped with screened RJ-45 sockets. It is suitable for 5 and 12V bus voltage.
![]() | Additional information about the standard s88-N which will be supported by other manufacturers as well can be found here: http://www.s88-N.eu. ![]() |
---|
If the screening of the bus connections in accordance to s88-N requires a connection to the layout ground is it possible to solder a grounded cable to the metal housing of a RJ-45 socket.
Instructions regarding this article can be found here: Downloads RM-88-N.
Instructions for all LDT-Components can be found here: Overview Downloads.
Sample-connections regarding this article can be found here:
Sample-Connection RM-88-N (3-rail conductor) and
Sample-Connection RM-88-N (2-rail conductor).
Sample-connections for all LDT-Components can be found here: Overview Sample-Connections.
Attention: Products can only be added to the Wish List, if you are registered as customer at the LDT WebShop or if you are initially registered by interest of our products.
![]() | Add to Wish List: RM-88-N-B (Part-No.: 310111): 16-fold Feedback Module as a kit (27,90 €*). Add to Wish List: RM-88-N-F (Part-No.: 310112): 16-fold Feedback Module as a finished module (37,90 €*). Add to Wish List: RM-88-N-G (Part-No.: 310113): 16-fold Feedback Module as a finished module in a case (41,50 €*). ![]() * All prices incl. VAT, plus Shipping. |
---|
The feedback module RM-88-N will be supplied without s88-bus cable. Please select a suitable bus cable (length and style) at the following table. For the s88-standard connection we supply an interference protected, twisted s88-bus cable with original s88-plugs at length of 0,5m, 1m and 2m. s88-standard connections are always required for the connection of the first feedback module to the command station or interface.
We offer for s88-bus connections in accordance to a blue screened patch cable with RJ-45 plugs at four different length of 0,5 to 3m.
The feedback module RM-88-N, RM-88-N-O and RM-GB-8-N can be connected between each other either via s88-standard connection “Kabel s88” or via “Kabel Patch” according to.
s88-standard connection with 2 original s88-plugs, gray cable, twisted, round. Plus pin bar for bus extension. |
---|
Kabel s88 0,5m |
Kabel s88 1m |
Kabel s88 2m |
![]() ![]() ![]() |
Kabel Patch 0,5m |
Kabel Patch 1m |
Kabel Patch 2m |
Kabel Patch 3m |