Writing /usr/www/users/ldt/newshop2/dokuwiki/data/meta/en/ab_ecos1_2lg.meta failed
ECoS 1 (50000) (2-rail conductor)
> To overview: sample connections sorted by digital command stations
> To overview: sample connections sorted by digital components
> To product selection: ECoS 1 (50000) DCC
description | file | edition |
---|---|---|
Digital-current ring conductor with multiple supply connection | page_349 | 08/2007 |
External supply to the Decoder | page_329 | 07/2020 |
Correct connection of the external supply voltage | page_506 | 07/2020 |
Seperate digital-current conductor for the decoder | page_350 | 09/2020 |
Ring conductor to the decoder | page_003 | 07/2020 |
Suppression of interferences caused by end-off switched turnouts | page_330 | 07/2020 |
PIKO A-rail drive switched via resistor | page_331 | 07/2020 |
Supply of monitored track sections (track occupancy feedback) / s88 standard cable | page_556 | 05/2020 |
Track occupancy feedback with one isolated rail / s88 standard cable | page_604 | 05/2020 |
Shuttle train line with one isolated rail / s88 standard cable | page_612 | 05/2020 |
Track occupancy feedback with two isolated rails / s88 standard cable | page_605 | 05/2020 |
Shuttle train line with two isolated rails / s88 standard cable | page_613 | 05/2020 |
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable | page_606 | 05/2020 |
Serveral track occupancy detection at a reversing loop with KSM-SG and RM-GB-8-N | page_726 | 07/2020 |
Occupancy detection with ECoSDetector 50094 at a reversing loop with KSM-SG | page_1705 | 07/2020 |
Track monitoring with two booster current circuits (with DB-2) / s88 standard cable | page_607 | 05/2020 |
Track section monitoring and switching off (voltage free) | page_592 | 03/2022 |
Monitoring of slow-down and stop-sections and common switching off (voltage free) | page_614 | 03/2022 |
Equivalent current at monitored and non-monitored areas | page_615 | 04/2020 |
Reed contacts for feedback (Standard) / s88 standard cable | page_689 | 09/2020 |
Reed contacts for feedback (Opto) / s88 standard cable | page_708 | 09/2020 |
Accelerated feedback via HSI-88 / s88 standard cable | page_578 | 09/2020 |
Driving and switching with ECoS 1 (50000) / feedback with HSI-88 | page_374 | 05/2020 |
Accelerated feedback via HSI-88-USB / s88 standard cable | page_582 | 09/2020 |
Driving and switching with ECoS 1 (50000) / feedback with HSI-88-USB | page_469 | 05/2020 |
Numbering the feedback registrations / s88 standard cable | page_909 | 05/2020 |
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N | page_915 | 05/2020 |
Numbering the feedback registrations (various feedback modules) / s88 standard cable | page_588 | 05/2020 |
Numbering the feedback modules / s88 standard cable | page_781 | 09/2020 |
Numbering the feedback modules / s88 standard cable | page_775 | 09/2020 |
Data switch DSW-88-N on ECoS 1 (50000) (various feedback modules) | page_1211 | 05/2020 |
Data switch DSW-88-N on ECoS 1 (50000) (RM-88-N-O) | page_1212 | 05/2020 |
Connecting DigitalBooster DB-2 or DB-4 via the 5-poles booster bus | page_348 | 06/2013 |
Connecting the DigitalBooster DB-2 via 5-poles booster bus | page_378 | 06/2020 |
Connecting the DigitalBooster DB-4 via 5-poles booster bus | page_934 | 06/2020 |
Connecting the DigitalBooster DB-4 via CDE-booster bus | page_1168 | 06/2013 |
Connecting the DigitalBooster DB-4 via CDE-booster bus | page_1174 | 06/2020 |
WatchDog decoder WD-DEC with ECoS 1 (50000) and DigitalBooster DB-2 | page_499 | 03/2020 |
GBS-DEC-DC/MM: external switchboard panel PC-controlled and ECoS 1 (50000) | page_1520 | 03/2020 |
GBS-DEC-DC/MM: s88-feedback bus branching via Data switch DSW-88-N with ECoS 1 (50000) | page_1222 | 03/2020 |
GBS-DEC-s88: external switchboard panel PC-controlled with ECoS 1 (50000) and RM-88-N | page_1527 | 03/2020 |
GBS-DEC-s88: external switchboard panel PC-controlled with ECoS 1 (50000) and RM-GB-8-N | page_1513 | 03/2020 |
Subject to technical changes and errors.
© 2022 by LDT
Märklin and Motorola are registered trade marks.