Writing /usr/www/users/ldt/newshop2/dokuwiki/data/meta/en/ab_ib_3lg.meta failed
Intellibox (3-rail conductor)
> To overview: sample connections sorted by digital command stations
> To overview: sample connections sorted by digital components
> To product selection: Intellibox Märklin-Motorola
description | file | edition |
---|---|---|
Digital-current ring conductor with multiple supply connection | page_011 | 04/2003 |
External supply to the Decoder | page_332 | 07/2020 |
Correct connection of the external AC supply voltage | page_509 | 07/2020 |
Seperate digital-current conductor for the decoder | page_012 | 01/2020 |
Ring conductor to the decoder | page_016 | 01/2020 |
Suppression of interferences caused by end-off switched turnouts | page_333 | 07/2020 |
Supply to monitored track sections (track occupancy feedback) / s88 standard cable | page_558 | 09/2020 |
Track monitoring via isolated center conductor / s88 standard cable | page_616 | 04/2020 |
Track section monitoring with total isolated track / s88 standard cable | page_617 | 04/2020 |
Track monitoring with two booster current circuits (with DB-2) / s88 standard cable | page_624 | 04/2020 |
Track monitoring with two booster current circuits (with Power 3) / s88 standard cable | page_621 | 04/2020 |
Track section monitoring and switching off (voltage free) | page_1344 | 03/2022 |
Reed contacts for feedback (Standard) / s88 standard cable | page_681 | 09/2020 |
Reed contacts for feedback (Opto) / s88 standard cable | page_700 | 09/2020 |
Track occupancy feedback via contact tracks (Standard) / s88 standard cable | page_683 | 09/2020 |
Track occupancy feedback via contact tracks (Opto) / s88 standard cable | page_702 | 09/2020 |
Accelerated feedback via HSI-88 / s88 standard cable | page_744 | 09/2020 |
Accelerated feedback via HSI-88 (with separate transformer for HSI-88) / s88 standard cable | page_736 | 09/2020 |
Reed contacts for feedback report (Standard) with seperate transformer for HSI-88-USB / s88 standard cable | page_752 | 09/2020 |
Track occupancy feedback via contact tracks (Standard) with seperate transformer for HSI-88-USB / s88 standard cable | page_760 | 09/2020 |
Driving and switching with Intellibox / feedback with HSI-88 | page_115 | 01/2020 |
Driving and switching with Intellibox / feedback with HSI-88-USB | page_393 | 05/2020 |
Numbering the feedback registrations / s88 standard cable | page_905 | 04/2020 |
Numbering the feedback registrations(RM-GB-8-N) / patch-cable to s88-N | page_911 | 04/2020 |
Numbering the feedback registrations (various feedback modules) / s88 standard cable | page_584 | 04/2020 |
Numbering the feedback modules / s88 standard cable | page_663 | 09/2020 |
Numbering the feedback modules / s88 standard cable | page_772 | 09/2020 |
Data switch DSW-88-N on Intellibox (various feedback modules) | page_1196 | 05/2020 |
Data switch DSW-88-N on Intellibox (RM-88-N-O) | page_1204 | 05/2020 |
Connecting the DigitalBooster DB-2 via 5-poles booster bus | page_177 | 01/2020 |
Connecting the DigitalBooster DB-4 via 5-poles booster bus | page_928 | 06/2020 |
Connecting the DigitalBooster DB-4 via CDE-booster bus | page_1352 | 06/2020 |
WatchDog decoder WD-DEC with Intellibox and DigitalBooster DB-2 | page_173 | 03/2020 |
WatchDog decoder WD-DEC with Intellibox and booster Power3 | page_153 | 03/2020 |
GBS-DEC-DC/MM: external switchboard panel PC-controlled and Intellibox | page_1516 | 03/2020 |
GBS-DEC-DC/MM: s88-feedback bus branching via Data switch DSW-88-N with Intellibox | page_1217 | 03/2020 |
GBS-DEC-DC/MM: external switchboard panel PC-controlled with Intellibox and HSI-88-USB | page_1537 | 03/2020 |
GBS-DEC-DC/MM: external switchboard panel PC-controlled with Intellibox and HSI-88 | page_1538 | 03/2020 |
GBS-DEC-s88: external switchboard panel PC-controlled with Intellibox and RM-88-N | page_1523 | 03/2020 |
GBS-DEC-s88: external switchboard panel PC-controlledwith Intellibox and RM-GB-8-N | page_1509 | 03/2020 |
Subject to technical changes and errors.
© 2022 by LDT
Märklin and Motorola are registered trade marks.