Writing /usr/www/users/ldt/newshop2/dokuwiki/data/meta/en/ab_redbox_3lg.meta failed
RedBox (3-rail conductor)
> To overview: sample connections sorted by digital command stations
> To overview: sample connections sorted by digital components
> To product selection: RedBox Märklin-Motorola
description | file | edition |
---|---|---|
Digital-current ring conductor with multiple supply connection (with DB-2) | page_1799 | 09/2020 |
Digital-current ring conductor with multiple supply connection (with DB-4) | page_1800 | 09/2020 |
External supply to the Decoder | page_332 | 07/2020 |
Correct connection of the external AC supply voltage | page_509 | 07/2020 |
Seperate digital-current conductor for the decoder (with DB-2) | page_1801 | 09/2020 |
Seperate digital-current conductor for the decoder (with DB-4) | page_1802 | 09/2020 |
Ring conductor to the decoder | page_016 | 01/2020 |
Suppression of interferences caused by end-off switched turnouts | page_333 | 07/2020 |
Supply to monitored track sections (track occupancy feedback) (with DB-2) / patch-cable to s88-N | page_1803 | 04/2020 |
Supply to monitored track sections (track occupancy feedback) (with DB-4) / patch-cable to s88-N | page_1804 | 04/2020 |
Track monitoring via isolated center conductor (with DB-2) / patch-cable to s88-N | page_1805 | 04/2020 |
Track monitoring via isolated center conductor (with DB-4) / patch-cable to s88-N | page_1806 | 04/2020 |
Track section monitoring with total isolated track (with DB-2) / patch-cable to s88-N | page_1807 | 04/2020 |
Track section monitoring with total isolated track (with DB-4) / patch-cable to s88-N | page_1808 | 04/2020 |
Track monitoring with two booster current circuits (with DB-2) / patch-cable to s88-N | page_1809 | 04/2020 |
Track monitoring with two booster current circuits (with DB-4) / patch-cable to s88-N | page_1810 | 04/2020 |
Track section monitoring and switching off (voltage free) | page_1344 | 03/2022 |
Reed contacts for feedback (Standard) (with DB-2) / patch-cable to s88-N | page_1811 | 09/2020 |
Reed contacts for feedback (Standard) (with DB-4) / patch-cable to s88-N | page_1812 | 09/2020 |
Reed contacts for feedback (Opto) (with DB-2) / patch-cable to s88-N | page_1813 | 09/2020 |
Reed contacts for feedback (Opto) (with DB-4) / patch-cable to s88-N | page_1814 | 09/2020 |
Track occupancy feedback via contact tracks (Standard) (with DB-2) / patch-cable to s88-N | page_1815 | 09/2020 |
Track occupancy feedback via contact tracks (Standard) (with DB-4) / patch-cable to s88-N | page_1816 | 09/2020 |
Track occupancy feedback via contact tracks (Opto) (with DB-2) / patch-cable to s88-N | page_1817 | 09/2020 |
Track occupancy feedback via contact tracks (Opto) (with DB-4) / patch-cable to s88-N | page_1818 | 09/2020 |
Driving and switching with RedBox / feedback with HSI-88 | page_1823 | 05/2020 |
Accelerated feedback via HSI-88 (with DB-2) / patch-cable to s88-N | page_1819 | 09/2020 |
Accelerated feedback via HSI-88 (with DB-4) / patch-cable to s88-N | page_1820 | 09/2020 |
Accelerated feedback via HSI-88 (with separate transformer for HSI-88) (with DB-2) / patch-cable to s88-N | page_1821 | 09/2020 |
Accelerated feedback via HSI-88 (with separate transformer for HSI-88) (with DB-4) / patch-cable to s88-N | page_1822 | 09/2020 |
Driving and switching with RedBox / feedback with HSI-88-USB | page_1828 | 05/2020 |
Accelerated feedback via HSI-88-USB (with DB-2) / patch-cable to s88-N | page_1824 | 09/2020 |
Accelerated feedback via HSI-88-USB (with DB-4) / patch-cable to s88-N | page_1825 | 09/2020 |
Accelerated feedback via HSI-88-USB (with separate transformer for HSI-88-USB) (with DB-2) / patch-cable to s88-N | page_1826 | 09/2020 |
Accelerated feedback via HSI-88-USB (with separate transformer for HSI-88-USB) (with DB-4) / patch-cable to s88-N | page_1827 | 09/2020 |
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N | page_1829 | 04/2020 |
Numbering the feedback registrations (various feedback modules) / patch-cable to s88-N | page_1830 | 04/2020 |
Numbering the feedback modules / patch-cable to s88-N | page_1831 | 09/2020 |
Numbering the feedback modules | page_1832 | 09/2020 |
Data switch DSW-88-N on RedBox (various feedback modules) | page_1833 | 05/2020 |
Data switch DSW-88-N on RedBox (RM-88-N-O) | page_1834 | 05/2020 |
Connecting the DigitalBooster DB-2 via 5-poles booster bus | page_1835 | 06/2020 |
Connecting the DigitalBooster DB-2 via Adapter Adap-CDE | page_1836 | 06/2020 |
Connecting the DigitalBooster DB-4 via 5-poles booster bus | page_1837 | 06/2020 |
Connecting the DigitalBooster DB-4 via CDE-booster bus | page_1838 | 06/2020 |
WatchDog decoder WD-DEC with RedBox and DigitalBooster DB-2 | page_1839 | 03/2020 |
GBS-DEC-DC/MM: external switchboard panel PC-controlled and RedBox | page_1840 | 03/2020 |
GBS-DEC-DC/MM: s88-feedback bus branching via Data switch DSW-88-N with RedBox | page_1841 | 03/2020 |
Subject to technical changes and errors.
© 2022 by LDT
Märklin and Motorola are registered trade marks.