 +====== Sample-Connections: Feedback modules with integrated occupancy detectors RM-GB-8 ====== 
 +== The RM-GB-8 is not anymore available. == 
 +** Please select the successor module [[en:rm-gb-8-n|RM-GB-8-N]]. ** 
 +\\  \\  
 +[[:en:ab_nml|> To overview: sample connections from not anymore available components and versions]]\\ 
 +[[:en:anschlussbeispiele|> To overview: sample connections for all available components]]\\ 
 +[[:en:rm-gb-8|> To product description: RM-GB-8]]\\ 
 +\\  
 +^__//description//__  ^__//file//__  ^__//edition//__  | 
 +^Intellibox (2-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track occupancy feedback with one isolated rail**   |**{{:de:anschlussbeispiele:page_017.pdf|page_017}}  **  |**01/2006**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track occupancy feedback with two isolated rails  ^{{:de:anschlussbeispiele:page_018.pdf|page_018}}   ^01/2006  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Numbering the feedback registrations**   |**{{:de:anschlussbeispiele:page_028.pdf|page_028}}  **  |**11/2004**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring with two booster current circuits (with DB-2)  ^{{:de:anschlussbeispiele:page_255.pdf|page_255}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track monitoring with two booster current circuits (with Power 3)**   |**{{:de:anschlussbeispiele:page_145.pdf|page_145}}  **  |**10/2005**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Occupancy detection at a reversing loop (with KSM1 from MÜT)  ^{{:de:anschlussbeispiele:page_345.pdf|page_345}}   ^01/2007  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track section monitoring and switching off (voltage free)**   |**{{:de:anschlussbeispiele:page_019.pdf|page_019}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Monitoring of slow-down and stop-sections and common switching off \\ {{:de:images:Ueberschrift_Einrueck.gif}}(voltage free)  ^{{:de:anschlussbeispiele:page_458.pdf|page_458}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Equivalent current at monitored and non-monitored areas**   |**{{:de:anschlussbeispiele:page_496.pdf|page_496}}  **  |**03/2008**  | 
 +^Intellibox (3-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track monitoring via isolated center conductor**   |**{{:de:anschlussbeispiele:page_022.pdf|page_022}}  **  |**03/2007**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track section monitoring with total isolated track  ^{{:de:anschlussbeispiele:page_023.pdf|page_023}}   ^03/2007  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Numbering the feedback registrations**   |**{{:de:anschlussbeispiele:page_028.pdf|page_028}}  **  |**11/2004**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring with two booster current circuit (with DB-2)  ^{{:de:anschlussbeispiele:page_254.pdf|page_254}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track monitoring with two booster current circuit (with Power 3)**   |**{{:de:anschlussbeispiele:page_143.pdf|page_143}}  **  |**10/2005**  | 
 +^TWIN-CENTER (2-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track monitoring with one isolated rail**   |**{{:de:anschlussbeispiele:page_020.pdf|page_020}}  **  |**11/2004**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring with two isolated rails  ^{{:de:anschlussbeispiele:page_021.pdf|page_021}}   ^11/2004  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Numbering the feedback registrations**   |**{{:de:anschlussbeispiele:page_027.pdf|page_027}}  **  |**11/2004**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring with two booster current circuit (with DB-2)  ^{{:de:anschlussbeispiele:page_252.pdf|page_252}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track monitoring with two booster current circuit (with TWIN-BOOSTER)**   |**{{:de:anschlussbeispiele:page_146.pdf|page_146}}  **  |**10/2005**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Occupancy detection at a reversing loop (with KSM1 from MÜT)  ^{{:de:anschlussbeispiele:page_356.pdf|page_356}}   ^01/2007  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track section monitoring and switching off (voltage free)**   |**{{:de:anschlussbeispiele:page_019.pdf|page_019}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Monitoring of slow-down and stop-sections and common switching off \\ {{:de:images:Ueberschrift_Einrueck.gif}}(voltage free)  ^{{:de:anschlussbeispiele:page_458.pdf|page_458}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Equivalent current at monitored and non-monitored areas**   |**{{:de:anschlussbeispiele:page_496.pdf|page_496}}  **  |**03/2008**  | 
 +^Control Unit (6021) Märklin-Digital (3-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track monitoring with isolated center conductor**   |**{{:de:anschlussbeispiele:page_024.pdf|page_024}}  **  |**11/2004**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring with total isolated track  ^{{:de:anschlussbeispiele:page_025.pdf|page_025}}   ^11/2004  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Numbering the feedback registrations at the Interface**   |**{{:de:anschlussbeispiele:page_091.pdf|page_091}}  **  |**11/2004**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring with two booster current circuit (with DB-2)  ^{{:de:anschlussbeispiele:page_253.pdf|page_253}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track monitoring with two booster current circuit (with Booster 6015)**   |**{{:de:anschlussbeispiele:page_144.pdf|page_144}}  **  |**10/2005**  | 
 +^EasyControl (3-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Supply to monitored track sections (track occupancy feedback)**   |**{{:de:anschlussbeispiele:page_303.pdf|page_303}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring via isolated center conductor  ^{{:de:anschlussbeispiele:page_305.pdf|page_305}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track section monitoring with total isolated track**   |**{{:de:anschlussbeispiele:page_307.pdf|page_307}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring with two booster current circuits (with DB-2)  ^{{:de:anschlussbeispiele:page_309.pdf|page_309}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Numbering the feedback registrations**   |**{{:de:anschlussbeispiele:page_310.pdf|page_310}}  **  |**07/2006**  | 
 +^EasyControl (2-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Supply of monitored track sections (track occupancy feedback)**   |**{{:de:anschlussbeispiele:page_302.pdf|page_302}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track occupancy feedback with one isolated rail  ^{{:de:anschlussbeispiele:page_304.pdf|page_304}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track occupancy feedback with two isolated rails**   |**{{:de:anschlussbeispiele:page_306.pdf|page_306}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring with two booster current circuits (with DB-2)  ^{{:de:anschlussbeispiele:page_308.pdf|page_308}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Numbering the feedback registrations**   |**{{:de:anschlussbeispiele:page_310.pdf|page_310}}  **  |**07/2006**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track section monitoring and switching off (voltage free)  ^{{:de:anschlussbeispiele:page_019.pdf|page_019}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Monitoring of slow-down and stop-sections and common switching off \\ {{:de:images:Normal_Einrueck.gif}}(voltage free)**   |**{{:de:anschlussbeispiele:page_458.pdf|page_458}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Equivalent current at monitored and non-monitored areas  ^{{:de:anschlussbeispiele:page_496.pdf|page_496}}   ^03/2008  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Accelerated feedback via HSI-88**   |**{{:de:anschlussbeispiele:page_319.pdf|page_319}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Accelerated feedback via HSI-88-USB  ^{{:de:anschlussbeispiele:page_471.pdf|page_471}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}GBS-DEC-s88: external switchboard panel PC-controlled with EasyControl and RM-GB-8**   |**{{:de:anschlussbeispiele:page_484.pdf|page_484}}  **  |**10/2020**  | 
 +^ECoS 2 (50200) (3-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Supply to monitored track sections (track occupancy feedback)**   |**{{:de:anschlussbeispiele:page_1063.pdf|page_1063}}  **  |**09/2010**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring via isolated center conductor  ^{{:de:anschlussbeispiele:page_1064.pdf|page_1064}}   ^09/2010  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track section monitoring with total isolated track**   |**{{:de:anschlussbeispiele:page_1065.pdf|page_1065}}  **  |**09/2010**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring with two booster current circuits (with DB-2)  ^{{:de:anschlussbeispiele:page_1066.pdf|page_1066}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Numbering the feedback registrations**   |**{{:de:anschlussbeispiele:page_1061.pdf|page_1061}}  **  |**09/2010**  | 
 +^ECoS 2 (50200) (2-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Supply of monitored track sections (track occupancy feedback)**   |**{{:de:anschlussbeispiele:page_1055.pdf|page_1055}}  **  |**09/2010**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track occupancy feedback with one isolated rail  ^{{:de:anschlussbeispiele:page_1056.pdf|page_1056}}   ^09/2010  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Shuttle train line with one isolated rail**   |**{{:de:anschlussbeispiele:page_1068.pdf|page_1068}}  **  |**09/2010**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track occupancy feedback with two isolated rails  ^{{:de:anschlussbeispiele:page_1057.pdf|page_1057}}   ^09/2010  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Shuttle train line with two isolated rails**   |**{{:de:anschlussbeispiele:page_1069.pdf|page_1069}}  **  |**09/2010**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Occupancy detection at a reversing loop (with KSM1 from MÜT)  ^{{:de:anschlussbeispiele:page_1058.pdf|page_1058}}   ^09/2010  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track monitoring with two booster current circuits (with DB-2)**   |**{{:de:anschlussbeispiele:page_1059.pdf|page_1059}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Numbering the feedback registrations  ^{{:de:anschlussbeispiele:page_1061.pdf|page_1061}}   ^09/2010  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track section monitoring and switching off (voltage free)**   |**{{:de:anschlussbeispiele:page_019.pdf|page_019}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Monitoring of slow-down and stop-sections and common switching off \\ {{:de:images:Ueberschrift_Einrueck.gif}}(voltage free)  ^{{:de:anschlussbeispiele:page_458.pdf|page_458}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Equivalent current at monitored and non-monitored areas**   |**{{:de:anschlussbeispiele:page_496.pdf|page_496}}  **  |**03/2008**  | 
 +^ECoS 1 (50000) (3-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Supply to monitored track sections (track occupancy feedback)**   |**{{:de:anschlussbeispiele:page_379.pdf|page_379}}  **  |**01/2008**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring via isolated center conductor  ^{{:de:anschlussbeispiele:page_380.pdf|page_380}}   ^08/2007  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track section monitoring with total isolated track**   |**{{:de:anschlussbeispiele:page_381.pdf|page_381}}  **  |**08/2007**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring with two booster current circuits (with DB-2)  ^{{:de:anschlussbeispiele:page_382.pdf|page_382}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Numbering the feedback registrations**   |**{{:de:anschlussbeispiele:page_375.pdf|page_375}}  **  |**03/2007**  | 
 +^ECoS 1 (50000) (2-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Supply of monitored track sections (track occupancy feedback)**   |**{{:de:anschlussbeispiele:page_366.pdf|page_366}}  **  |**08/2007**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track occupancy feedback with one isolated rail  ^{{:de:anschlussbeispiele:page_367.pdf|page_367}}   ^08/2007  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Shuttle train line with one isolated rail**   |**{{:de:anschlussbeispiele:page_449.pdf|page_449}}  **  |**10/2007**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track occupancy feedback with two isolated rails  ^{{:de:anschlussbeispiele:page_368.pdf|page_368}}   ^08/2007  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Shuttle train line with two isolated rails**   |**{{:de:anschlussbeispiele:page_452.pdf|page_452}}  **  |**11/2007**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Occupancy detection at a reversing loop (with KSM1 from MÜT)  ^{{:de:anschlussbeispiele:page_369.pdf|page_369}}   ^08/2007  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track monitoring with two booster current circuits (with DB-2)**   |**{{:de:anschlussbeispiele:page_370.pdf|page_370}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Numbering the feedback registrations  ^{{:de:anschlussbeispiele:page_375.pdf|page_375}}   ^03/2007  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track section monitoring and switching off (voltage free)**   |**{{:de:anschlussbeispiele:page_019.pdf|page_019}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Monitoring of slow-down and stop-sections and common switching off \\ {{:de:images:Ueberschrift_Einrueck.gif}}(voltage free)  ^{{:de:anschlussbeispiele:page_458.pdf|page_458}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Equivalent current at monitored and non-monitored areas**   |**{{:de:anschlussbeispiele:page_496.pdf|page_496}}  **  |**03/2008**  | 
 +^DiCoStation (3-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Supply to monitored track sections (track occupancy feedback)**   |**{{:de:anschlussbeispiele:page_417.pdf|page_417}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring via isolated center conductor  ^{{:de:anschlussbeispiele:page_418.pdf|page_418}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track section monitoring with total isolated track**   |**{{:de:anschlussbeispiele:page_419.pdf|page_419}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track monitoring with two booster current circuits (with DB-2)  ^{{:de:anschlussbeispiele:page_420.pdf|page_420}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Numbering the feedback registrations**   |**{{:de:anschlussbeispiele:page_413.pdf|page_413}}  **  |**10/2020**  | 
 +^DiCoStation (2-rail conductor):  ^     ^     | 
 +|**{{:de:images:Normal_Einrueck.gif}}Supply of monitored track sections (track occupancy feedback)**   |**{{:de:anschlussbeispiele:page_406.pdf|page_406}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Track occupancy feedback with one isolated rail  ^{{:de:anschlussbeispiele:page_407.pdf|page_407}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track occupancy feedback with two isolated rails**   |**{{:de:anschlussbeispiele:page_408.pdf|page_408}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Occupancy detection at a reversing loop (with KSM1 from MÜT)  ^{{:de:anschlussbeispiele:page_409.pdf|page_409}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track monitoring with two booster current circuits (with DB-2)**   |**{{:de:anschlussbeispiele:page_410.pdf|page_410}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Numbering the feedback registrations  ^{{:de:anschlussbeispiele:page_413.pdf|page_413}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Track section monitoring and switching off (voltage free)**   |**{{:de:anschlussbeispiele:page_019.pdf|page_019}}  **  |**10/2020**  | 
 +^{{:de:images:Ueberschrift_Einrueck.gif}}Monitoring of slow-down and stop-sections and common switching off \\ {{:de:images:Ueberschrift_Einrueck.gif}}(voltage free)  ^{{:de:anschlussbeispiele:page_458.pdf|page_458}}   ^10/2020  | 
 +|**{{:de:images:Normal_Einrueck.gif}}Equivalent current at monitored and non-monitored areas**   |**{{:de:anschlussbeispiele:page_496.pdf|page_496}}  **  |**03/2008**  | 
 +^Combine existing RM-GB-8 with RM-GB-8-N (1)  ^{{:de:anschlussbeispiele:page_1120.pdf|page_1120}}   ^04/2020  | 
 +|**Combine existing RM-GB-8 with RM-GB-8-N (2)**   |**{{:de:anschlussbeispiele:page_1121.pdf|page_1121}}  **  |**04/2020**  | 
 +\\  
 +Subject to technical changes and errors.\\  © 2020 by LDT\\ <sub> Märklin and Motorola are registered trade marks.</sub> \\ 
 