ECoS 2 (50200) (2-rail conductor)
> To overview: sample connections sorted by digital command stations
> To overview: sample connections sorted by digital components
> To product selection: ECoS 2 (50200) DCC
description | file | edition |
---|---|---|
Digital-current ring conductor with multiple supply connection | page_1051 | 09/2010 |
External supply to the Decoder | page_329 | 07/2020 |
Correct connection of the external supply voltage | page_506 | 07/2020 |
Seperate digital-current conductor for the decoder | page_1052 | 09/2020 |
Ring conductor to the decoder | page_003 | 07/2020 |
Suppression of interferences caused by end-off switched turnouts | page_330 | 07/2020 |
PIKO A-rail drive switched via resistor | page_331 | 07/2020 |
Supply of monitored track sections (track occupancy feedback) / s88 standard cable | page_1072 | 05/2020 |
Track occupancy feedback with one isolated rail / s88 standard cable | page_1078 | 05/2020 |
Shuttle train line with one isolated rail / s88 standard cable | page_1082 | 05/2020 |
Track occupancy feedback with two isolated rails / s88 standard cable | page_1079 | 05/2020 |
Shuttle train line with two isolated rails / s88 standard cable | page_1083 | 05/2020 |
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable | page_1080 | 05/2020 |
Serveral track occupancy detection at a reversing loop with KSM-SG and RM-GB-8-N | page_726 | 07/2020 |
Occupancy detection with ECoSDetector 50094 at a reversing loop with KSM-SG | page_1705 | 07/2020 |
Track monitoring with two booster current circuits (with DB-2) / s88 standard cable | page_1081 | 05/2020 |
Track section monitoring and switching off (voltage free) | page_592 | 03/2022 |
Monitoring of slow-down and stop-sections and common switching off (voltage free) | page_614 | 03/2022 |
Equivalent current at monitored and non-monitored areas | page_615 | 04/2020 |
Reed contacts for feedback (Standard) / s88 standard cable | page_1087 | 09/2020 |
Reed contacts for feedback (Opto) / s88 standard cable | page_1090 | 09/2020 |
Accelerated feedback via HSI-88 / s88 standard cable | page_1075 | 09/2020 |
Driving and switching with ECoS 2 (50200) / feedback with HSI-88 | page_1060 | 05/2020 |
Accelerated feedback via HSI-88-USB / s88 standard cable | page_1076 | 09/2020 |
Driving and switching with ECoS 2 (50200) / feedback with HSI-88-USB | page_1070 | 05/2020 |
Numbering the feedback registrations / s88 standard cable | page_1102 | 05/2020 |
Numbering the feedback registrations / patch-cable to s88-N | page_1103 | 05/2020 |
Numbering the feedback registrations (various feedback modules) / s88 standard cable | page_1077 | 05/2020 |
Numbering the feedback modules / s88 standard cable | page_1098 | 09/2020 |
Numbering the feedback modules / s88 standard cable | page_1097 | 09/2020 |
Data switch DSW-88-N on ECoS 2 (50200) (various feedback modules) | page_1213 | 05/2020 |
Data switch DSW-88-N on ECoS 2 (50200) (RM-88-N-O) | page_1214 | 05/2020 |
Connecting DigitalBooster DB-2 or DB-4 via the 5-poles booster bus | page_1050 | 06/2013 |
Connecting the DigitalBooster DB-2 via 5-poles booster bus | page_1062 | 06/2020 |
Connecting the DigitalBooster DB-4 via 5-poles booster bus | page_1105 | 06/2020 |
Connecting external Stop/Go push-buttons (AC voltage supply) | page_1336 | 09/2020 |
Connecting external Stop/Go push-buttons (DC voltage supply) | page_1451 | 09/2020 |
Connecting the DigitalBooster DB-4 via CDE-booster bus | page_1167 | 06/2013 |
Connecting the DigitalBooster DB-4 via CDE-booster bus | page_1172 | 06/2020 |
WatchDog decoder WD-DEC with ECoS 2 (50200) and DigitalBooster DB-2 | page_1071 | 03/2020 |
GBS-DEC-DC/MM: external switchboard panel PC-controlled and ECoS 2 (50200) | page_1532 | 03/2020 |
GBS-DEC-DC/MM: s88-feedback bus branching via Data switch DSW-88-N with ECoS 2 (50200) | page_1223 | 03/2020 |
GBS-DEC-s88: external switchboard panel PC-controlled with ECoS 2 (50200) and RM-88-N | page_1533 | 03/2020 |
GBS-DEC-s88: external switchboard panel PC-controlled with ECoS 2 (50200) and RM-GB-8-N | page_1531 | 03/2020 |
Subject to technical changes and errors.