Writing /usr/www/users/ldt/newshop2/dokuwiki/data/meta/en/ab_ib_2lg.meta failed

Intellibox (2-rail conductor)

> To overview: sample connections sorted by digital command stations
> To overview: sample connections sorted by digital components
> To product selection: Intellibox DCC

description file edition
Digital-current ring conductor with multiple supply connection page_000 04/2003
External supply to the Decoder page_329 07/2020
Correct connection of the external supply voltage page_506 07/2020
Seperate digital-current conductor for the decoder page_001 09/2020
Ring conductor to the decoder page_003 07/2020
Suppression of interferences caused by end-off switched turnouts page_330 07/2020
PIKO A-rail drive switched via resistor page_331 07/2020
Supply of monitored track sections (track occupancy feedback) / s88 standard cable page_553 09/2020
Track occupancy feedback with one isolated rail / s88 standard cable page_590 04/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_591 04/2020
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable page_551 04/2020
Serveral track occupancy detection at a reversing loop with KSM-SG and RM-GB-8-N page_726 07/2020
Track monitoring with two booster current circuits (with DB-2) / s88 standard cable page_600 04/2020
Track monitoring with two booster current circuits (with Power 3) / s88 standard cable page_595 04/2020
Track section monitoring and switching off (voltage free) page_592 03/2022
Monitoring of slow-down and stop-sections and common switching off (voltage free) page_614 03/2022
Equivalent current at monitored and non-monitored areas page_615 04/2020
Reed contacts for feedback (Standard) / s88 standard cable page_684 09/2020
Reed contacts for feedback (Opto) / s88 standard cable page_703 09/2020
Accelerated feedback via HSI-88 / s88 standard cable page_575 09/2020
Driving and switching with Intellibox / feedback with HSI-88 page_115 01/2020
Driving and switching with Intellibox / feedback with HSI-88-USB page_393 05/2020
Supply to monitored track sections (track occupancy feedback) / s88 standard cable page_580 09/2020
Numbering the feedback registrations (RM-GB-8-N) / s88 standard cable page_905 04/2020
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N page_911 04/2020
Numbering the feedback registrations (various feedback modules) / s88 standard cable page_584 04/2020
Numbering the feedback modules / s88 standard cable page_663 09/2020
Numbering the feedback modules / s88 standard cable page_772 09/2020
Data switch DSW-88-N on Intellibox (various feedback modules) page_1196 05/2020
Data switch DSW-88-N on Intellibox (RM-88-N-O) page_1204 05/2020
Connecting the DigitalBooster DB-2 via 5-poles booster bus page_178 06/2020
Connecting the DigitalBooster DB-4 via 5-poles booster bus page_929 06/2020
Connecting the DigitalBooster DB-4 via CDE-booster bus page_1353 06/2020
WatchDog decoder WD-DEC with Intellibox and DigitalBooster DB-2 page_173 03/2020
WatchDog decoder WD-DEC with Intellibox and booster Power3 page_153 03/2020
GBS-DEC-DC/MM: external switchboard panel PC-controlled and Intellibox page_1516 03/2020
GBS-DEC-DC/MM: s88-feedback bus branching via Data switch DSW-88-N with Intellibox page_1217 03/2020
GBS-DEC-DC/MM: external switchboard panel PC-controlled with Intellibox and HSI-88-USB page_1537 03/2020
GBS-DEC-DC/MM: external switchboard panel PC-controlled with Intellibox and HSI-88 page_1538 03/2020
GBS-DEC-s88: external switchboard panel PC-controlled with Intellibox and RM-88-N page_1523 03/2020
GBS-DEC-s88: external switchboard panel PC-controlledwith Intellibox and RM-GB-8-N page_1509 03/2020

Subject to technical changes and errors.
© 2022 by LDT
Märklin and Motorola are registered trade marks.

 
Recent changes RSS feed Creative Commons License Donate Powered by PHP Valid XHTML 1.0 Valid CSS Driven by DokuWiki Design by Chirripó