RM-DEC-88 and RM-DEC-88-O

16-fold feedback modules

100% compatible with the s88 from our Digital-Professional-Series !
The feedback modules RM-DEC-88 and RM-DEC-88-O are not anymore available.

Please select the successor modules RM-88-N or the RM-88-N-O.

RM-DEC-88 Opto and RM-DEC-88 for MEMORY, INTERFACE and Intellibox / TWIN-CENTER with 75cm connection cable.

Features of the RM-DEC-88 and RM-DEC-88-O

  • For connection to: INTERFACE (up to 31 modules), MEMORY (up to 3 modules), Intellibox/TWIN-CENTER (up to 31 modules) and our High Speed Interface HSI-88 (up to 31 modules).
  • The feedback modules RM-DEC-88 and RM-DEC-88 Opto can be combined with the s88 feedback modules from Märklin and other manufacturers as required.
  • Simple and secure connection of switch rails, contact rails, occupancy sensors or reed-contacts by screw clips.
  • The RM-DEC-88 Opto is equipped with additional opto coupler and therefore extremely protected against interference.
  • Our feedback modules RM-DEC-88 and RM-DEC-88 Opto from our Digital-Professional-Series can be operated without any difficulty from your digitally controlled model railroad as these decoders are 100% compatible with the feedback module s88.
  • Suitable installation material can be ordered under: accessories.
From the table below you can see which feedback module may be used with the contacts of your model railroad:
Kind of contacts RM-DEC-88 RM-DEC-88 Opto
Circuit-track(3-conductor rail system) X X
Contact-track (3-conductor rail system) X X
Reed-contact, Occupancy detector with relay output
(2-conductor and 3-conductor rail system)
X X
Track contact-switch (2-conductor rail system) X
Connection cable between contacts and feedback module
more than 2 meters (2-conductor and 3-conductor rail system)
X
Occupancy detector on a 2-conductor rail system
(with additional module see description below)
Better to use our octal feedback module with
integrated occupancy detection (RM-GB-8-N).
X
Turnout-feedback (with additional module-
see description below)
X
  • Track occupancy detection at two-rail 2-conductor systems: Contrary to the Märklin 3-conductor rail-system can the occupancy of direct-current rails only be reliably realized with electronic circuitry which measure the current at the track section. For this application is it recommended to use our 8-fold feedback module with integrated track occupancy monitor (RM-GB-8-N ). In case you integrated already some occupancy circuits you can combine those with our feedback modules RM-DEC-88-Opto provided that the occupancy circuits have no potential-free outputs. Four of such modules can be connected directly to a feedback module RM-DEC-88-Opto and report the occupancy situation of 16 track sections to the control unit. If the occupancy monitor has potential-free report outputs (e.g. relay contacts) you can apply our feedback module RM-DEC-88.
  • Feedback from turnouts: If you require the feedback of the actual turnout position to the control unit (or personal computer) you can apply our feedback module RM-DEC-88-Opto. For further information please attend to our description under Feedback of the turnout position.
  • Extended connection cable: All LDT feedback modules will be supplied ex factory together with a 75 cm interference protected, twisted s88-bus cable.
Additionally we offer connection cables at low cost:
s88-standard connection with 2 original s88-plugs,
gray cable, twisted, round. Plus pin bar for bus extension.
Kabel s88 0,5m
Kabel s88 1m
Kabel s88 2m

Downloads

Instructions regarding this not anymore available article can be found here: Downloads RM-DEC-88 and RM-DEC-88-O.
Instructions for all LDT-Components can be found here: Übersicht Downloads.

Sample-Connections

Sample-connections regarding this not anymore available article can be found here:
Sample-Connections RM-DEC-88 and RM-DEC-88-O.
Sample-connections for all LDT-Components can be found here: Overview Sample-Connections.